Video of the Day

Saturday, January 18, 2014

Kitchen Exhaustion Fan Controller

Exhaustion fan is a very important element in kitchens. Here may be a easy circuit to manage kitchen fans by monitoring the ambient temperature. it's engineered round the renowned precision integrated temperature sensor chip LM35 (IC1). remainder of the circuit may be a non-traditional electromagnetic relay driver wired round the fashionable LED driver LM3914 (IC2). User will switch 3 presetted temperature levels employing a jumper/slide switch (JP1), that determines the warmth level to activate the relay and hence the electrical exhaustion fan wired through the relay contacts. It works off 12V DC power offer.

Kitchen Exhaustion Fan Controller  Circuit Schematic




Only one adjustment is needed during this kitchen Exhaustion fan controller circuit. when construction, set jumper purpose in its 1st position, ie base terminal of T1 is connected to pin thirteen of IC2 and alter the preset P1 fastidiously in order that relay RL1 is energised when ambient temperature level reaches close to 29oC. but this is often not terribly vital as you'll choose any threshold level by connecting the jumper points to alternative unused output pins of IC2 (here solely three outputs are used).


Kirish

Author & Editor

Has laoreet percipitur ad. Vide interesset in mei, no his legimus verterem. Et nostrum imperdiet nostrum imperdiet appellantur appellantur usu, mnesarchum referrentur id vim.